| ConfirmFlow/Vorsite2000 | |
![]() |
|
| System Features : | |
|
-
|
Use of Vortex technology to confirm flow of chemical upon receipt of a chemical request signal (Automatic Bulk supply or Pre-weighed chemical) |
|
-
|
Critical Spike/ Dispense of Chemical is acknowledged by the ConfirmFlow/Vorsite2000 ™ and an electrical signal output is emitted should the Spike valve fails to open and flow of chemical is not registered |
|
-
|
System capable to provide Audio-visual signals (Light tower style) as required for manufacturing environments |
|
-
|
Vortex meters (PVDF of PTFE)are compatible with most semiconductor process chemicals: HF, HCl, NH4OH, H2O2, H2SO4, etc. |
| Specifications : | |
|
-
|
Flow Span: 1/2” Diam: 2.3-18.9 Lpm |
|
-
|
Connection: Flaretek™ |
|
-
|
Material:PVDF or PTFE |
|
-
|
Output: 4-20 m |
|
-
|
Accuracy: ±.75% of user |
|
-
|
Two Relay outputs Remote LCD (Up to 5 meters) |
![]() |
|
|
353 Main Street Pennsburg, PA 18073 |
|